Aseptic technique and daily decontamination will eliminate the majority of contaminants.
Cleaning procedure for biological safety cabinet.
The biological safety officer will determine the type of decontamination necessary.
It should be noted that the.
5 1 2 dedust the biosafety cabinet daily externally with a clean dry cloth.
How to clean a biological safety cabinet lafw hood.
Spray the surfaces of all items placed into the cabinet with 70 ethanol to minimize the introduction of contaminants into the bsc.
10 easy steps to cleaning a contaminated surface in the biosafety cabinet.
In addition periodic and thorough decontamination routines including disinfecting all removable parts and surfaces is recommended by the manufacturer and is a good laboratory practice to reduce wear on the equipment and provide greater safety to you your samples and the environment.
Remember to wear appropriate ppe and leave the biosafety cabinet on during spill cleanup.
The biohazard bag should never be kept outside the cabinet.
Biological safety cabinet sop bsc 01.
Cleaning and disinfection 1.
Typically surface decontamination is adequate however there are instances such as extensive repair inside the cabinet envelope or hepa filter replacement that will require gas decontamination.
Allow to air dry.
Put the waste from the spill into a biohazard bag inside the cabinet.
Once the cabinet is empty you should allow 20 30 minutes to thoroughly decontaminate all interior work surfaces making sure to clean the back and side of the cabinet and the interior of the glass.
5 1 3 once in a week remove adhered dust by wet mopping using soap solution.
Hepa filters are defined as air cleaning devices that have a proven minimum removal efficiency of 99 97 of particles in the air equal to 0 3.
Once the cabinet has been operational for 15 minutes disinfect all interior surfaces of the cabinet thoroughly by spraying with 70 ethanol.
This may take more or less time depending on the disinfectant and the microbiological agent used.
The interior surfaces should also be wiped with an appropriate disinfectant that would kill any microorganisms that could be found in the cabinet.
To begin apply disinfect to a towel and decontaminate and remove items from the area of the spill.
How to clean a biological safety cabinet lafw hood.
When work is completed all equipment and supplies from the bsc should be decontaminated and removed from the cabinet.
If the biological safety cabinet is turned off between aseptic processes for routine maintenance or any other reason it should be operated long enough to allow complete purging of room air from the critical area for at least 30 minutes then cleaned and disinfected before use.
Afterward wipe the surface with a clean dry cloth to remove the moisture.
μ microns in diameter with higher efficiency for both larger and.